Hot and Cold Supplies
Hot and cold supplies are the pipes that bring water to each bathroom fitting, with isolating valves, mixing valves and backflow protection along the way.
- Fitted by
- Plumber
- Main runs and bath
- 22 mm
- Basins, showers and WC
- 15 mm
- Final connections
- 15 mm or flexible connectors
- In the models
- Bathroom
What it is
The hot and cold supplies are the pipes that bring water to the bath, shower, basins and WC. Hot water comes from the boiler or cylinder and cold from the mains, usually in copper or plastic pipe, in 22 mm for the main runs and the bath and 15 mm to the other fittings. They run through the ceiling void, the risers and the walls to each outlet.
Along the way are valves that make the system safe and serviceable. Isolating valves let each fitting be shut off on its own. A thermostatic mixing valve blends hot and cold to a safer temperature for basins. A pipe interrupter or other backflow device stops dirty water being drawn back into the supply from a fitting whose outlet sits below the rim, like a bath filler in the overflow.
What it does
- Bringing water to each fittingThe pipes deliver hot and cold at the pressure and flow each fitting needs, sized so a shower does not run cold when a tap is opened.
- Keeping it safeMixing valves limit hot water temperatures, and backflow devices stop used water getting back into the drinking water supply.
- Making it serviceableIsolating valves let a tap, valve or cistern be worked on without draining the whole system.
Where you’ll find it
- Ceiling and floor voidsThe main runs, clipped to joists or run between them, as here above the suspended ceiling.
- Service risers and wallsDropping in the risers and stud walls to concealed valves and wall mixers.
- Under fittingsThe last connections to taps, cisterns and valves, often on flexible connectors.
Types
Supplies are grouped by the pipe material, and by the valves fitted along them.
Copper
Copper tube to BS EN 1057, joined with soldered or compression fittings, or press fittings. Rigid, long lasting and fire safe.
Sizes
Pipe sizes are set by the flow each fitting needs and how far it is from the source.
- Main runs and bath22 mm
- Basins, showers and WC15 mm
- Final connections15 mm or flexible connectors
- Bath hot water in new homes48 degrees at most
- Pipe clipsat close centres along each run
How to specify
Plan the supplies with the hot water system and the fittings, since the pipe sizes, valves and routes depend on both.
- 1Source and pressureCheck the hot water system and the cold mains pressure, and size the pipes so every fitting gets enough flow, even with several running.
- 2ValvesPut an isolating valve on every outlet, a thermostatic mixing valve where hot water must be limited, and backflow protection where any outlet sits below its fitting's rim.
- 3RoutesRun pipes where they can be clipped and reached, avoid notching joists where possible, and keep hot and cold apart so the cold stays cold.
Things to watch
Bath temperature. In a new home, Approved Document G requirement G3(4) limits the hot water delivered to a bath to 48 degrees.
Backflow. The Water Supply (Water Fittings) Regulations 1999 require backflow protection suited to each fitting, such as a pipe interrupter on a bath filler set below the rim.
Isolation. Isolating valves on each fitting make servicing quick. Fit them where they can be reached.
Water efficiency. Approved Document G sets a target for water use in new homes, which the choice of fittings and flow rates helps meet.
Insulation. Insulate hot pipes to save heat and cold pipes in cold voids to stop them freezing or sweating.
Fixings and joists. Pipes through joists should be in holes on the centreline, not deep notches. Mark pipe routes in walls and floors.
Works with
The hot and cold supplies work with the elements around them.
- Showerand bath are fed through the shower valve and the filler.
- Basinmixers are fed here through a thermostatic mixing valve.
- WCtakes its cold supply at the cistern's valve.
- Pattressing and noggingshold the valves and outlet elbows firm.
Popular manufacturers
- Visit website
Aalberts IPS
The UK home of the Pegler and Yorkshire brands, making copper and press fittings, valves and taps for water supplies.
- Visit website
Reliance Water Controls
A UK maker of water valves, including Heatguard thermostatic mixing valves, isolating valves and backflow devices.
- Visit website
Altecnic
The UK arm of Caleffi, making thermostatic mixing valves, backflow prevention and other valves for heating and water systems.