Extract Fan
A bathroom extract fan pulls steam out of the room through a duct to the outside, stopping condensation and mould. Rates, types and how they are ducted.
- Fitted by
- Electrician
- Intermittent extract rate
- at least 15 litres per second
- Duct size
- commonly 100 mm
- Overrun timer
- keeps it running after use
- In the models
- Bathroom
What it is
A bathroom extract fan pulls warm, wet air out of the room before the steam from a bath or shower can condense on cold surfaces and cause mould. It sits in the ceiling or high on a wall, ideally near the bath or shower, and pushes the air through a duct to the outside through a wall or the roof.
Fans are rated by how much air they move, in litres per second, and the Building Regulations set a minimum for a bathroom. Most are wired so they run with the light and keep going for a set time after, on a timer, or switch on by themselves when the air is humid. In this bathroom a ceiling fan runs through a 100 mm rigid duct in the ceiling void.
What it does
- Clearing steamThe fan draws moist air out while you wash and keeps going afterwards, so the room dries out instead of the steam condensing.
- Preventing mouldLess condensation means less damp on walls, ceilings and grout, and so less mould and peeling paint.
- Clearing smellsIt also clears smells, and draws fresh air in from the rest of the home, usually under the door.
Where you’ll find it
- In the ceilingOver or near the bath or shower, ducted through the ceiling void to an outside wall or the roof, as here.
- On an outside wallThrough the wall straight to the outside, the simplest where a wall is available.
- In the loft or voidAn inline fan in the duct, away from the room, with only a grille in the ceiling, for quieter running.
Types
Extract fans are grouped by where the fan sits and how it runs.
Axial
A simple propeller fan for short duct runs, straight through a wall or ceiling. Cheap and quiet, but weak against long ducts.
Sizes
Extract rates for bathrooms are set out in Approved Document F.
- Intermittent extract rateat least 15 litres per second
- Duct sizecommonly 100 mm
- Overrun timerkeeps it running after use
- Supplyvia a fused isolator, three pole for timer fans
- Grille sizeabout 150 to 200 mm square
How to specify
Choose the fan with its duct route, since the length and bends of the duct decide how much air the fan can really move.
- 1Rate and typePick a fan that meets the Approved Document F rate through the duct you have, not just in open air, choosing centrifugal or inline for longer runs.
- 2Position and ductPlace it near the bath or shower, away from the door, and plan a short duct with few bends to the outside, insulated through cold voids.
- 3Controls and wiringChoose timer, humidity or continuous control, and have it wired with an isolator outside the room, with a fitting rated for its zone.
Things to watch
Extract rate. Approved Document F asks for at least 15 litres per second for a bathroom on an intermittent fan.
Air in. Air has to get into the room to replace what is extracted, usually through a gap under the door. Approved Document F sets out the gap needed.
Duct run. Long, kinked or flexible ducts cut the airflow badly. Rigid duct, short and straight, works best.
Condensation in the duct. Insulate the duct through a cold loft and fall it to the outside, so condensed water does not run back into the fan.
Zones. A fan in zone 1 over the bath must be rated for that zone, and is often a low voltage fan. Check against BS 7671 Section 701.
Backdraught shutter. A shutter stops cold air blowing back in when the fan is off.
Works with
The extract fan works with the elements around it.
- Ceilingcarries the fan, with the duct in the void above.
- Sockets and switchescovers its supply and the isolator.
- Tilingand tanking stay drier because it clears the steam.
Popular manufacturers
- Visit website
EnviroVent
A UK maker of ventilation, including the Silent 100 bathroom fan in this model and continuous running fans.
- Visit website
Vent-Axia
A long established UK maker of extract fans and ventilation systems for homes, from simple bathroom fans to whole house systems.
- Visit website
Xpelair
A UK ventilation brand within Glen Dimplex, making bathroom and kitchen extract fans and continuous running units.